Hobart 169 Power rinse temperature not reached.
Severidad Media 169
🔍
Diagnóstico Inmediato
Power rinse temperature not reached.
Power rinse tank sensor QTM4 (AI7)
⚙️
Causa Técnica
| Componente | Problema detectado | Cómo verificarlo |
|---|---|---|
| Power rinse tank sensor QTM4 (AI7) | Power rinse temperature not reached. |
🛠️
Solución — Pasos de Reparación
- 1 Paso 1 Check high limit
- 2 Paso 2 Check power rinse tank thermistor
- 3 Paso 3 Check power rinse tank heaters, wiring and contactor
- 4 Paso 4 Ensure thermal paste between thermistor and tank wall
- 5 Paso 5 Check if water is below heater level
- 6 Paso 6 Check if tank fill valve is stuck open