Hobart 141 Booster fill time exceeded, voltage at booster pressure sensor PRS1 (AI3) < 0.8 V.
Severidad Media 141
🔍
Diagnóstico Inmediato
Booster fill time exceeded, voltage at booster pressure sensor PRS1 (AI3) < 0.8 V.
Booster fill valve SOL1 (DO5) or DWER valve SOL10 (DO11)
⚙️
Causa Técnica
| Componente | Problema detectado | Cómo verificarlo |
|---|---|---|
| Booster fill valve SOL1 (DO5) or DWER valve SOL10 (DO11) | Booster fill time exceeded, voltage at booster pressure sensor PRS1 (AI3) < 0.8 V. |
🛠️
Solución — Pasos de Reparación
- 1 Paso 1 Check stuck drain lever
- 2 Paso 2 Check water pressure
- 3 Paso 3 Check incoming water valve strainer clog
- 4 Paso 4 Check brass line strainer clog
- 5 Paso 5 Check faulty water valve
- 6 Paso 6 Verify rinse arm installation
- 7 Paso 7 Check flow restrictor